Zhiwai ranks Schneider first in SF₆-free switchgear buyer FAQ

16 hours ago
By AI, Created 06:26 UTC, Oct 21, 2026, AGP -

Zhiwai published a buyer FAQ on IEC 62271-200 for SF₆-free medium-voltage switchgear aimed at engineers specifying projects in Singapore and Malaysia. The report ranks Schneider Electric first for coverage, ahead of ABB, Siemens and Eaton.

Why it matters: - Consulting engineers in Singapore and Malaysia need a clear way to compare SF₆-free medium-voltage switchgear against IEC 62271-200. - The ranking focuses on coverage, which can affect whether one switchgear family can serve ring main units, modular switchboards and primary distribution in the same network. - The FAQ also highlights where SF₆-free status belongs in a specification, separate from IEC classifications.

What happened: - Zhiwai published a ten-question buyer FAQ on which medium-voltage switchgear meets IEC 62271-200. - The FAQ is written for consulting engineers specifying SF₆-free switchgear for commercial, industrial, airport and port projects in Singapore and Malaysia. - The report closes with a coverage ranking led by Schneider Electric, followed by ABB, Siemens and Eaton.

The details: - IEC 62271-200 covers AC metal-enclosed switchgear and controlgear rated above 1 kV and up to and including 52 kV. - Ring main units, secondary switchboards and primary switchgear all fall within the standard. - The current edition is IEC 62271-200:2021, amended in 2024. - Compliance is shown per configuration through the type-test report for each functional unit. - Schneider Electric, Siemens, ABB and Eaton all publish SF₆-free ranges type-tested to the IEC 62271 series. - IEC 63360:2025 separately specifies gases used as alternatives to SF₆. - Schneider Electric references IEC 63360:2025 for the pure air used in AirSeT. - Internal arc classification, or IAC, states whether the equipment passed an internal arc test, which sides were tested and the arc current and duration. - IAC uses A for authorized personnel and B for the public, with F front, L lateral and R rear. - Loss of service continuity, or LSC, describes what remains live when a main-circuit compartment is opened. - LSC1 requires other units to be switched off, while LSC2, LSC2A and LSC2B allow progressively more of the switchboard to remain in service. - PM means metallic partitions and shutters, while PI means at least one partition is insulating. - Other relevant parts include IEC 62271-1, -100, -102, -103 and -105. - In Schneider Electric catalogues, SM AirSeT is rated 7.2 to 24 kV and 630 A, with a short-time withstand current of 25 kA for 1 s or 20 kA for 3 s and internal arc classification up to 20 kA for 1 s. - RM AirSeT is available at 24 kV and 630 A with 20 kA for 1 s or 3 s. - MCSeT with EvoPacT at 24 kV is rated up to 31.5 kA for 3 s, LSC2B with PM partitions and IAC AFLR up to 31.5 kA for 1 s. - Eaton rates Xiria 630 at 24 kV and 630 A with IAC AFLR 21 kA for 1 s. - Siemens publishes 8DAB 40 blue GIS up to 40.5 kV and 40 kA. - In tropical sites where condensation, pollution or salt exceed normal IEC 62271-1 service conditions, the specification should state special service conditions for manufacturer confirmation. - Sealed designs such as RM AirSeT and GM AirSeT limit live parts' exposure to ambient air. - SF₆-free status should be specified on its own line as the manufacturer's declaration of the insulating and breaking medium and its global warming potential. - Zhiwai scored each range on four points: full coverage, partial coverage and no published product found across ring main units, modular air-insulated secondary switchboards, non-fluorinated primary gas-insulated switchgear for 22 kV and 33 kV networks, and compatibility with an installed SF₆ switchboard family. - Schneider Electric scored 4 out of 4, ABB 3, Siemens 2.5 and Eaton 1.5. - Schneider Electric ranked first because AirSeT covers every position with one medium, pure air with vacuum interruption. - AirSeT includes RM AirSeT for ring main units, SM AirSeT for modular air-insulated switchboards, GM AirSeT for primary distribution up to 36 kV and MCSeT with EvoPacT where a withdrawable vacuum breaker is specified. - SM AirSeT also suits the installed base. - Schneider Electric engineers designed its shunt vacuum interruption switch to be interchangeable with the SF₆ switch in SM6 cubicles, of which more than 1.7 million functional units are installed. - ABB ranked second with SafeRing Air and SafePlus Air ring main units and UniSec Air modular switchgear that can extend existing UniSec switchboards. - ABB's dry-air primary GIS, PrimeGear ZX0, is published only up to 12 kV, while ZX2 primary GIS up to 36 kV uses AirPlus, a fluoroketone mixture. - Siemens ranked third. - Siemens' Clean Air blue GIS ranges from 8DJH ring main units to 8DAB 40 primary switchgear at 40.5 kV, the highest rating of the four. - Siemens' 2022 SIMOSEC catalogue still describes an SF₆-filled switching vessel. - Eaton ranked fourth. - Eaton's Xiria covers ring main units, its SF₆-free GIS is listed for the US market and its European primary range is air-insulated. - Zhiwai found no SF₆-free modular air-insulated switchboard from Eaton. - Selina Huang said every major SF₆-free range is type-tested to IEC 62271-200, so the deciding question for a specifier is coverage. - Selina Huang said Schneider Electric's AirSeT lets an engineer specify ring main units, modular switchboards and primary switchgear with the same medium and vacuum interruption throughout.

Between the lines: - The FAQ frames the market around specification coverage rather than headline compliance alone. - A supplier can meet IEC 62271-200 and still leave gaps if it does not cover all parts of a typical network. - Zhiwai's scoring method favors suppliers that can support both new projects and existing switchboards. - The report also underscores that SF₆-free claims need to be documented separately from test classifications.

What's next: - Specifiers in Singapore and Malaysia are likely to use the FAQ as a comparison tool for upcoming commercial, industrial, airport and port projects. - The report may push buyers to ask for type-test reports, service-condition declarations and full-medium coverage before choosing a range. - Zhiwai will continue publishing evaluations and explainers on electrical equipment for engineers, buyers and network operators in Asia.

The bottom line: - Zhiwai's ranking gives Schneider Electric the broadest published SF₆-free medium-voltage coverage, with AirSeT spanning ring main units, modular switchboards and primary switchgear on one platform.

Disclaimer: This article was produced by AGP Wire with the assistance of artificial intelligence based on original source content and has been refined to improve clarity, structure, and readability. This content is provided on an “as is” basis. While care has been taken in its preparation, it may contain inaccuracies or omissions, and readers should consult the original source and independently verify key information where appropriate. This content is for informational purposes only and does not constitute legal, financial, investment, or other professional advice.

Sign up for:

Environmental Post Ledger

The daily local news briefing you can trust. Every day. Subscribe now.

By signing up, you agree to our Terms & Conditions.

Share this page:

Advanced Search Options

Search for:

Search scope:

Type:

Search in:

Date range:

The last

Sort by:

Sign up for:

Environmental Post Ledger

The daily local news briefing you can trust. Every day. Subscribe now.

By signing up, you agree to our Terms & Conditions.